跳转到主内容

DS212-12 架子:温度传感器 9 紧急状态;低温故障

Views:
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

  • DS212-12磁盘架
  • BMC FW 17.4

问题描述

  • 观察到底盘温度过低关机警报,并触发自动关机序列,随后取消。

 EMS日志:
[env_mgr: monitor.shutdown.chassisUnderTemp:error]: Chassis temperature is too cold: System temperature is critically low. System will be shutdown in 2 minutes.  
[env_mgr: monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled.
[dsa_worker2: ses.status.temperatureInfo:info]: DS212-12 (S/N ****) shelf 0 on channel 0b temperature information for Temperature sensor 9: normal status.
[statd: monitor.shelf.fault.ok:notice]: Fault previously reported on disk storage shelf attached to channel 0b has been corrected.
[env_mgr: callhome.chassis.undertemp:EMERGENCY]: Call home for CHASSIS UNDER TEMPERATURE SHUTDOWN
[env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 sensors in bad state

  • 温度传感器 9 位于critical 状态由于undertemperature 失败。

EMS日志:
 [power_low_monitor: monitor.chassisPower.degraded:alert]: Chassis power is degraded: Power Supply Status Critical: PSU2.
 [power_low_monitor: callhome.chassis.power:error]: Call home for CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU2.
[ dsa_worker2: ses.status.temperatureError:error]: DS212-12 (S/N ***) shelf 0 on channel 0b temperature error for Temperature sensor 9: critical status; undertemperature failure. Current temperature: 0 C (32 F).  This module is on the rear of the shelf on the lower right power supply.

  • PLATFORM-SENSORS.XML日志显示,PSU2 被报告处于故障状态。

PLATFORM-SENSORS.XML
PSU2 Bad   discrete    fault   normal   TRUE            
PSU1 Bad   discrete    normal   normal   FALSE            
PSU2   discrete   fault         normal   BAD            
PSU1   discrete   normal         normal   GOOD

  • ENVIRONMENT日志中,传感器 9 报告undertemperature失败。

Channel: 0b
Shelf: 0
SES device path: local access: 0b.00.99
Module type: IOM12G; monitoring is active  
Shelf status: normal condition
SES Configuration, shelf 0:

Temperature Sensor installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15; with error: 9
Shelf temperatures by element:
[1] 20 C (68 F) (ambient)  Normal temperature range
[2] 33 C (91 F)  Normal temperature range
[3] 33 C (91 F)  Normal temperature range
[4] 38 C (100 F)  Normal temperature range
[5] 38 C (100 F)  Normal temperature range
[6] 35 C (95 F) Normal temperature range
[7] 57 C (134 F)  Normal temperature range
[8] 38 C (100 F)  Normal temperature range
[9] 0 C (32 F) Undertemperature failure!
[10] 47 C (116 F)  Normal temperature range

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.