由于单个磁盘出现故障、磁盘/磁盘架计数不匹配
适用场景
问题描述
EMS
ReportHA GROUP ERROR: DISK/SHELF COUNT MISMATCH
。- ADP配置的磁盘单独分布到两个节点。
disk_P1无响应且磁盘已损坏、但disk_P2仍包含在该ggr.
NodeA:
Broken disks
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
not responding 0b.00.18P1 0b 0 18 SA:A 0 SAS 10000 1689530/3460157952 1689538/3460174336 (fast zeroed)
NodeB:
Aggregate nodeB_aggr0 (online, raid_dp, fast zeroed) (block checksums)
Plex /nodeB_aggr0/plex0 (online, normal, active, pool0)
RAID group /nodeB_aggr0/plex0/rg0 (normal, block checksums)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
data 0b.00.12P2 0b 0 12 SA:B 0 SAS 10000 23956/49062912 23964/49079296 (fast zeroed)
data 0b.00.16P2 0b 0 16 SA:B 0 SAS 10000 23956/49062912 23964/49079296 (fast zeroed)
data 0b.00.18P2 0b 0 18 SA:B 0 SAS 10000 23956/49062912 23964/49079296 (fast zeroed)