由于机箱风扇故障、报告了"有故障的FanXFruFault"警报
- Views:
- 6
- Visibility:
- Public
- Votes:
- 0
- Category:
- ontap-9
- Specialty:
- hw<a>2008704817</a><a>进行翻译</a>
- Last Updated:
适用场景
- ONTAP 9
- AFF A400
- FAS9000
- FAS8700
- FAS8300
问题描述
- 事件日志中的风扇模块报告了以下错误:
[Node1: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Fan2_2 (failed)
[Node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: Fan2_2
[Node1: monitor: monitor.globalStatus.critical:EMERGENCY]: One fan has failed: SysFan2 F2.
[Node1: cphmd: hm.alert.raised:alert]: Alert Id = CriticalFan2FruFaultAlert , Alerting Resource = 021XXXXXXXX882 raised by monitor chassis
[Node1: mgwd: callhome.hm.alert.critical:alert]: Call home for Health Monitor process cphm: CriticalFan2FruFaultAlert[021XXXXXXXX882].
SP-LATEST-IPMI
AutoSupport部分显示受影响风扇的严重状态:
======================================
hsamcmd --fault-show-all
===============================
tag origin fld fault reason count time
---- ------- ---- ------------- ------ -----
1 0x5 /chassis-1/fan-2 ipmi Fan2_Speed2 lower non-critical 1 Tue May 9 19:20:38 2023
2 0x5 /chassis-1/fan-2 ipmi Fan2_Speed2 lower critical 1 Tue May 9 19:20:38 2023
FAN2:
Fan2_Status | 0x0 | discrete | Ready | na | na | na | na
Fan2_Current | 6.150 | Amps | ok | 0.000 | 0.500 | 10.000 | 12.000
Fan2_Speed1 | 8300.000 | RPM | ok | 1000.000 | 1250.000 | 9750.000 | 10000.000
Fan2_Speed2 | 0.000 | RPM | cr | 1000.000 | 1250.000 | 9750.000 | 10000.000
Fan2_Speed3 | 8300.000 | RPM | ok | 1000.000 | 1250.000 | 9750.000 | 10000.000
Fan2_Speed4 | 8250.000 | RPM | ok | 1000.000 | 1250.000 | 9750.000 | 10000.000