跳转到主内容

控制器温度传感器 MemoryX_Hot 报告已断言

Views:
86
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • ONTAP 9
  • AFF 系统
  • FAS 系统

问题

  • 控制器故障 LED 亮起
  • 来自SP-LATEST-IPMI 日志的传感器报告为 Asserted
    • Memory_Hot
    • Memory0_Hot 
    •  Memory1_Hot 
======================================
/usr/local/bin/ipmi sensors
===============================
Sensor Name    | Current   | Unit    | Status   | LCR    | LNC    | UNC    | UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
Memory0_Hot    | 0x0     | discrete  | Deasserted | na     | na     | na     | na
CPU1_Error    | 0x0     | discrete  | Deasserted | na     | na     | na     | na
CPU1_Therm_Trip  | 0x0     | discrete  | Deasserted | na     | na     | na     | na
CPU1_Hot     | 0x0     | discrete  | Deasserted | na     | na     | na     | na
Memory1_Hot    | 0x0     | discrete  | Asserted  | na     | na     | na     | na
PCH_Hot      | 0x0     | discrete  | Deasserted | na     | na     | na     | na

HSAM OS(0x5):cmd(1) FLD(controller-b):fault(Temperature Sensor 9 Fault)

hsamcmd --fault-show-all
========================
tag  origin  fld                    fault reason                   count  time
---- ------- ----                   -------------                   ------ -----
2   0x5    /chassis-1/controller-b          Temperature Sensor 9 Fault            1    

::> system environment sensors show -state !normal

Node Sensor State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------ ----------- -------- -------- ------- -------
node1
Memory1 Hot  fault HOT

  • SP-reboot 不清除此传感器状态

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.