跳转到主内容

由于CMOS电池、控制器故障LED亮起

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用场景

  • FAS9000  / AFF A700
  • ONTAP 9

问题描述

  • 节点 在 SP-LATEST-IPMI 上报告P3-3电池状态为“严重不足”:

tag  origin  fld                    fault reason                   count  time
---- ------- ----                   -------------                   ------ -----
2   0x5    /chassis-1/controller-a/coin-1      ipmi P3V_BATT lower non-critical         1    Thu Jan  1 00:02:49 1970
3   0x5    /chassis-1/controller-a/coin-1      ipmi P3V_BATT lower critical           1    Thu Jan  1 00:02:49 1970

Fault Lights On:
       /chassis-1                                        2
       /chassis-1/controller-a                                  2
       /chassis-1/controller-a/coin-1

Sensor Name        State      Current   Critical    Warning    Warning   Critical
                     Reading     Low      Low      High     High
-------------------------------------------------------------------------------------------------
P3V Batt          critlow       0 mV    2100 mV    2200 mV    3400 mV    3500 mV

  • 币形电池报告FRU LED亮起

FRU LEDs status
======================
FRU LED ID 01 = PCM FAULT LED
FRU LED ID 03 = SYS FAULT LED
FRU LED ID 41 = Coin Cell FAULT LED
FRU LED ID 1 is on
FRU LED ID 3 is on
FRU LED ID 41 is on

  • 节点报告RTC电池电量严重不足 

[?] env_mgr: monitor.rtcLowPower:error]: Real-time clock battery is dangerously low. Replace it at the next available maintenance window.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.