问题描述

  • 从 9.13.1P13 升级到 9.15.1P11 后,集群报告连续的“vifmgr.cluscheck.ctdpktloss:从集群 LIF 执行 ping 操作时继续丢失数据包”警报。
cluster1::event log> show -event *vifmgr.cluscheck.ctdpktloss*
Time         Node       Severity    Event
------------------- ---------------- ------------- ---------------------------
6/18/2025 09:51:03  cluster1-01    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from cluster lif cluster1-01_clus8 (node cluster1-01) to cluster lif cluster1-02_clus8 (node cluster1-02).
6/18/2025 09:50:41  cluster1-01    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from cluster lif cluster1-01_clus8 (node cluster1-01) to cluster lif cluster1-02_clus7 (node cluster1-02).
6/18/2025 09:50:19  cluster1-01    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from cluster lif cluster1-01_clus8 (node cluster1-01) to cluster lif cluster1-02_clus6 (node cluster1-02).
6/18/2025 09:49:57  cluster1-01    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from cluster lif cluster1-01_clus8 (node cluster1-01) to cluster lif cluster1-02_clus5 (node cluster1-02).
6/18/2025 09:49:24  cluster1-01    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from cluster lif cluster1-01_clus8 (node cluster1-01) to cluster lif cluster1-02_clus4 (node cluster1-02).
6/18/2025 09:43:39  cluster1-02    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from
cluster lif cluster1-02_clus8 (nodecluster1-02) to cluster lif cluster1-01_clus8 (node cluster1-01).
6/18/2025 09:42:54  cluster1-02    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from cluster lif cluster1-02_clus7 (node cluster1-02) to cluster lif cluster1-01_clus7 (node cluster1-01).
6/18/2025 09:42:10  cluster1-02    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from cluster lif cluster1-02_clus6 (node cluster1-02) to cluster lif cluster1-01_clus6 (node cluster1-01).
6/18/2025 09:41:25  cluster1-02    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from cluster lif cluster1-02_clus5 (node cluster1-02) to cluster lif cluster1-01_clus5 (node cluster1-01).
6/18/2025 09:40:39  cluster1-02    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from cluster lif cluster1-02_clus4 (node cluster1-02) to cluster lif cluster1-01_clus4 (node cluster1-01).
  • 集群端口已启动,集群 LIF 位于其主端口。
  • 集群端口上未观察到任何错误或丢弃。
  • 此集群最近从使用NetApp CN1610 交换机的集群转换为无交换机集群。
  • 此处使用的集群端口为 e4a、e4b、e4c、e4d、e8a、e8b、e8c、e8d,并且它们配置为分支模式。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.