问题描述
- 正在报告以下系统运行状况警报:
SwitchIslIfDownWarn_Alert
、SwitchUnreachable_Alert
和UnsupportedSwitch_Alert
。
Cluster1::*> system health alert show
Node: Cluster1-01
Alert ID: SwitchUnreachable_Alert
Resource: Old_Switch(FXXXXXXK4)
Severity: Major
Indication Time: Thu Feb 27 10:49:10 2025
Suppress: false
Acknowledge: false
Probable Cause: The ethernet switch's IP address is not reachable from
the local node.
Possible Effect: Monitoring of the switch and log collection will not
function.
Corrective Actions: Ensure that the IP address is reachable or specify the
correct reachable IP address.
- 正在为集群中既未使用也看不到的旧交换机配置报告警报。
Cluster1::*> system switch ethernet show
Switch Type Address Model
--------------------------- ------------------ ---------------- ---------------
Switch1(FXXXXXXJH) cluster-network 10.XXX.XX.48 N9K-C9336C-FX2
Serial Number: FXXXXXXJH
Is Monitored: true
Reason: None
Software Version: Cisco Nexus Operating System (NX-OS) Software, Version
10.2(5)
Version Source: CDP/ISDP
Switch2(FXXXXXXK4) cluster-network 10.XXX.XX.47 N9K-C9336C-FX2
Serial Number: FXXXXXXK4
Is Monitored: true
Reason: None
Software Version: Cisco Nexus Operating System (NX-OS) Software, Version
10.2(5)
Version Source: SNMP
2 entries were displayed.
- 警报中提到的旧交换机以前在使用中、后来被删除、并使用新的IP地址重新添加到CSHM中。