适用场景

  • ONTAP 9
  • FAS/AFA系统
  • 集群交换机

问题描述

  • 正在报告以下系统运行状况警报:SwitchIslIfDownWarn_AlertSwitchUnreachable_AlertUnsupportedSwitch_Alert 。 

Cluster1::*> system health alert show
    Node: Cluster1-01
        Alert ID: SwitchUnreachable_Alert
       Resource: Old_Switch(FXXXXXXK4)
        Severity: Major
        Indication Time: Thu Feb 27 10:49:10 2025
        Suppress: false
        Acknowledge: false
       Probable Cause: The ethernet switch's IP address is not reachable from
                     the local node.
       Possible Effect: Monitoring of the switch and log collection will not
                     function.
       Corrective Actions: Ensure that the IP address is reachable or specify the
                     correct reachable IP address.

  • 正在为集群中既未使用也看不到的旧交换机配置报告警报。

Cluster1::*> system switch ethernet show
Switch                      Type               Address          Model
--------------------------- ------------------ ---------------- ---------------
Switch1(FXXXXXXJH)            cluster-network    10.XXX.XX.48    N9K-C9336C-FX2
     Serial Number: FXXXXXXJH
      Is Monitored: true
            Reason: None
  Software Version: Cisco Nexus Operating System (NX-OS) Software, Version
                    10.2(5)
    Version Source: CDP/ISDP
Switch2(FXXXXXXK4)          cluster-network    10.XXX.XX.47    N9K-C9336C-FX2
     Serial Number: FXXXXXXK4
      Is Monitored: true
            Reason: None
  Software Version: Cisco Nexus Operating System (NX-OS) Software, Version
                    10.2(5)
    Version Source: SNMP
2 entries were displayed.

  • 警报中提到的旧交换机以前在使用中、后来被删除、并使用新的IP地址重新添加到CSHM中。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.