从FAS9300平台重复执行集群端口链路关闭/启动操作
适用场景
FAS8300
问题描述
- 两个集群端口的集群端口链路关闭/启动重复
[?] Sun Aug 06 05:22:50 [node01: mgmt_port_link_status_poll: netif.linkDown:info]: Ethernet e0c: Link down, check cable.
[?] Sun Aug 06 05:22:50 [node01: mgmt_port_link_status_poll: netif.linkDown:info]: Ethernet e0d: Link down, check cable.
[?] Sun Aug 06 05:22:53 [node01: vifmgr: vifmgr.portdown:notice]: A link down event was received on node node01, port e0c.
[?] Sun Aug 06 05:22:53 [node01: vifmgr: vifmgr.clus.linkdown:EMERGENCY]: The cluster port e0c on node node01 has gone down unexpectedly.
[?] Sun Aug 06 05:22:53 [node01: vifmgr: vifmgr.portdown:notice]: A link down event was received on node node01, port e0d.
[?] Sun Aug 06 05:22:53 [node01: vifmgr: vifmgr.clus.linkdown:EMERGENCY]: The cluster port e0d on node node01 has gone down unexpectedly
[?] Sun Aug 06 05:22:53 [node01: mgmt_port_link_status_poll: netif.linkUp:info]: Ethernet e0d: Link up.
[?] Sun Aug 06 05:22:53 [node01: mgmt_port_link_status_poll: netif.linkUp:info]: Ethernet e0c: Link up.
[?] Sun Aug 06 05:22:56 [node01: vifmgr: vifmgr.portup:notice]: A link up event was received on node node01, port e0d.
[?] Sun Aug 06 05:22:56 [node01: vifmgr: vifmgr.portup:notice]: A link up event was received on node node01, port e0c.
=-=-=-=-=-= Sun Aug 06 2023, 05:24:51 EMS-LOG-FILE.GZ 2 lines
Sun Aug 06 05:22:53 [node01: vifmgr: vifmgr.portdown:notice]: A link down event was received on node node01, port e0c.
Sun Aug 06 05:22:53 [node01: vifmgr: vifmgr.portdown:notice]: A link down event was received on node node01, port e0d.
=-=-=-=-=-= Sun Aug 06 2023, 05:24:51 EMS-LOG-FILE.GZ 2 lines
Sun Aug 06 05:22:53 [node02: vifmgr: vifmgr.portdown:notice]: A link down event was received on node node02, port e0c.
Sun Aug 06 05:22:53 [node02: vifmgr: vifmgr.portdown:notice]: A link down event was received on node node02, port e0d.
sysconfig -a
NetApp Release 9.7P7: Thu Aug 27 16:59:02 EDT 2020
Model Name: FAS8300
slot 0: 40G/100G Ethernet Controller CX5
e0c MAC Address: xx:xx:xx:xx:xx:xx (auto-100g_cr4-fd-up)
QSFP Vendor: Amphenol
QSFP Part Number: 112-00595
QSFP Serial Number: APFxxxxxxxxxxx
e0d MAC Address: xx:xx:xx:xx:xx:xx (auto-100g_cr4-fd-up)
QSFP Vendor: Amphenol
QSFP Part Number: 112-00595
QSFP Serial Number: APFxxxxxxxxxxx
Device Type: CX5 PSID(NAP0000000005)
Firmware Version: 16.26.4012
- 无交换机配置
Enable Switchless Cluster: true
- 重新拔插和更换集群电缆无法清除此问题描述