跳转到主内容

集群对等体在 2 节点 Stretch MetroCluster 上不可用

Views:
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • ONTAP 9.6 及更高版本
  • 对于 ONTAP 9.5RC1 到 9.5P2(含) 请点击此处
  • 集群对等
  • 加密算法
  • 2 节点 Stretch MCC

问题描述

  • MGWD 手动重新启动后,集群对等体变得不可用,PSK 密码丢失。
  • 尝试创建集群对等体失败,并显示以下错误消息:
  • Error: command failed: Using peer-address XX.XXX.XX.X: An introductory RPC to the peer address "XX.XX.XX.XX" failed to connect: RPC: Remote system error [from mgwd on node "XXXXXXXXX" (VSID: -1) to xcintro at XX.XX.XX.XX].  Verify that the peer address is correct and try again.

  • 升级到本知识库的"适用于"部分中提到的某个版本后,现有集群对等关系也可能会出现这些错误。
  • 在双节点 MetroCluster 系统中,ONTAP 升级后的切回失败,出现以下错误:
  • Cluster_A1::*> metrocluster switchback -simulate

    Error: command failed: Failed to retrieve system image status information for all
    nodes. Reason: Failed to contact peer cluster "Cluster_B1" at addresses:
    10.XX.XX.3, 10.XX.XX.4. RPC: Remote system error [from mgwd on node
    "Node_A1" (VSID: -1) to mgwd at 10.XX.XX.3, 10.XX.XX.4]. Verify that the
    nodes are healthy using the "cluster show" command and that cluster peering
    is available using the "cluster peer show" command, then retry the
    operation.

  • InterclusterBrokenConnectionAlert 可能会在运行状况监控中报告。
  • cluster peer show output 将远程集群的可用性报告为 Unavailable.
  • cluster peer health show 为空:
  • ::> cluster peer health show
    This table is currently empty

  • 端口 11104 无响应:
  • ::*> system node systemshell -node Node_A1 nc -zv 10.XX.XX.3 11104
    nc: connect to 10.XX.XX.3 port 11104 (tcp) failed: Connection refused

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.