跳转到主内容

双节点无交换机集群中的集群互连链路断开

Views:
379
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • FAS 系统
  • AFF 系统
  • 双节点无交换机集群

问题

  • 集群端口在双节点无交换机集群中相互连接 ,如下例所示:
    • 节点-1 e0a  <-> 节点-2 e0a
    • 节点-1 e0b  <-> 节点-2 e0b
  • sysconfig -a 日志显示两个 CLuster 端口均已关闭。

slot 0: 10 Gigabit Ethernet Controller IX5-SFP+
  e0a MAC Address:    **** (auto-unknown-fd-down)
      SFP Vendor:         Amphenol
      SFP Part Number:    616310000
      SFP Serial Number:  ****
  e0b MAC Address:    **** (auto-unknown-fd-down)
      SFP Vendor:         Amphenol
      SFP Part Number:    616310000
      SFP Serial Number:  ****
  Device Type:        X550EM
  Firmware Version:   0.0-0.0

  • 在这种情况下,如果其中一个集群 端口在一个节点上发生故障,则该 集群互连链路 在两个节点上同时发生故障。这 会导致节点与集群断开连接。

例如:

Tue Jul 27 02:24:18 IST [Node-1: kernel: netif.linkDown:info]: Ethernet e0a: Link down, check cable.
Tue Jul 27 02:24:21 IST [Node-1: vifmgr: vifmgr.portdown:notice]: A link down event was received on node Node-1, port e0a.
Tue Jul 27 02:24:24 IST [Node-1: vifmgr: vifmgr.clus.linkdown:EMERGENCY]: The cluster port e0a on node Node-1 has gone down unexpectedly
                         
Tue Jul 27 02:24:18 IST [Node-2: kernel: netif.linkDown:info]: Ethernet e0a: Link down, check cable.
Tue Jul 27 02:24:21 IST [Node-2: vifmgr: vifmgr.portdown:notice]: A link down event was received on node Node-2, port e0a.
Tue Jul 27 02:24:25 IST [Node-2: vifmgr: vifmgr.clus.linkdown:EMERGENCY]: The cluster port e0a on node Node-2 has gone down unexpectedly.

  • 托管在发生故障的集群端口上的集群 LIF  将移动到两个节点上的冗余集群端口。

例如:

Tue Jul 27 02:24:24 IST [Node-1: vifmgr: vifmgr.lifsuccessfullymoved:notice]: LIF Node-1_clus1 (on virtual server 5432198765), IP address 169.X.X.X, is now hosted on node Node-1, port e0b.
Tue Jul 27 02:24:25 IST [Node-2: vifmgr: vifmgr.lifsuccessfullymoved:notice]: LIF Node-2_clus1 (on virtual server 5432198765), IP address 169.X.X.X, is now hosted on node Node-2, port e0b.                 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.