跳转到主内容

集群网络丢包警报

Views:
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • NetApp ONTAP 9.16.1P7 (集群模式)
  • FAS9000 系列
  • 集群网络交换机

问题

集群报告了与集群 LIF 之间丢包相关的间歇性警报,包括:

[vifmgr.cluscheck.droppedlarge:alert]: Partial packet loss when pinging from cluster LIF Node1_clus2 (node 1) to cluster LIF Node1_clus1 (node 2).
[vifmgr.cluscheck.droppedall:alert]: Total packet loss when pinging from cluster LIF Node1_clus2 (node 1) to cluster LIF Node1_clus1 (node 2).
[vifmgr.cluscheck.droppednone:notice]: No packet loss when pinging from cluster LIF Node1_clus2
(node 1) to cluster LIF Node1_clus1 (node 2).

Sw1:
Ethernet1/XX
transceiver is present
type is QSFP-40G-CSR4
name is CISCO-FINISAR
part number is FTL410QD4C-C1
revision is A
serial number is FIW253301AR
nominal bitrate is 10300 MBit/sec per channel
Link length supported for 50/125um OM2 fiber is 82 m
Link length supported for 50/125um OM3 fiber is 300 m
cisco id is 13
cisco extended id number is 16
cisco part number is 10-2837-03
cisco product id is QSFP-40G-CSR4
cisco version id is V03

Lane Number:1 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 29.69 C 75.00 C -5.00 C 70.00 C 0.00 C
Voltage 3.30 V 3.63 V 2.97 V 3.46 V 3.10 V
Current 7.55 mA 15.00 mA 2.00 mA 14.00 mA 3.00 mA
Tx Power -1.48 dBm 2.99 dBm -11.30 dBm 0.00 dBm -7.30 dBm
Rx Power -10.79 dBm - 2.99 dBm -13.90 dBm 0.00 dBm -9.90 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning

Lane Number:2 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 29.69 C 75.00 C -5.00 C 70.00 C 0.00 C
Voltage 3.30 V 3.63 V 2.97 V 3.46 V 3.10 V
Current 7.36 mA 15.00 mA 2.00 mA 14.00 mA 3.00 mA
Tx Power -2.07 dBm 2.99 dBm -11.30 dBm 0.00 dBm -7.30 dBm
Rx Power -11.85 dBm - 2.99 dBm -13.90 dBm 0.00 dBm -9.90 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning

Lane Number:3 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 29.69 C 75.00 C -5.00 C 70.00 C 0.00 C
Voltage 3.30 V 3.63 V 2.97 V 3.46 V 3.10 V
Current 7.68 mA 15.00 mA 2.00 mA 14.00 mA 3.00 mA
Tx Power -2.15 dBm 2.99 dBm -11.30 dBm 0.00 dBm -7.30 dBm
Rx Power -10.60 dBm - 2.99 dBm -13.90 dBm 0.00 dBm -9.90 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning

Lane Number:4 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 29.69 C 75.00 C -5.00 C 70.00 C 0.00 C
Voltage 3.30 V 3.63 V 2.97 V 3.46 V 3.10 V
Current 7.48 mA 15.00 mA 2.00 mA 14.00 mA 3.00 mA
Tx Power -1.99 dBm 2.99 dBm -11.30 dBm 0.00 dBm -7.30 dBm
Rx Power -10.55 dBm - 2.99 dBm -13.90 dBm 0.00 dBm -9.90 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------

集群端口统计显示错误为零,但交换机接口诊断显示 ISL 端口 Ethernet1/xx 和 sw1 上的 port-channel1 存在输入错误,以及连接到多个节点端口的接口上存在输出错误。

光学诊断显示,某交换机上 Ethernet1/xx 的接收光功率偏低,接近警告阈值。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.