Cisco C9336C 电源出现故障
适用场景
- 集群网络交换机
- Cisco C9336C
- 电源( PSU )
问题描述
- 有关交换机 PSU 故障的 ONTAP EMS 通知:
HA Group Notification (Health Monitor process cshm: SwitchFanUnknown_Alert[sw02(serial_number)/PowerSupply-1 Fan-1]) ALERT- 交换机日志 `
show environment` 确认损坏的 PSU :
`show environment`Fan:---------------------------------------------------------------------------Fan Model Hw Direction Status---------------------------------------------------------------------------Fan1(sys_fan1) NXA-FAN-65CFM-PE -- back-to-front OkFan2(sys_fan2) NXA-FAN-65CFM-PE -- back-to-front OkFan3(sys_fan3) NXA-FAN-65CFM-PE -- back-to-front OkFan_in_PS1 -- -- back-to-front NoneFan_in_PS2 -- -- back-to-front OkFan Zone Speed: Zone 1: 0xb3Fan Air Filter : NotSupported电源:
Voltage: 12 VoltsPower Actual Actual TotalSupply Model Output Input Capacity Status(Watts ) (Watts ) (Watts )------- ---------- --------------- ------ ---------- --------------------1 NXA-PAC-1100W-PE2 0 W 0 W 0 W Fail/Shut2 NXA-PAC-1100W-PE2 280 W 298 W 1100 W Ok- 电源线和电源连接正常