致电主页查看运行状况监控进程 nphm : Data ONTAP 中的 BootmediaReplaceAlert
适用于
- FAS 系列
- AFF 系列
问题
- Data ONTAP 会生成运行状况警报 "BootmediaReplaceAlert"
- EMS 日志会报告警报。
Sun Aug 16 00:36:02 CDT [system2-01: mgwd: callhome.hm.alert.critical:alert]: Call home for Health Monitor process nphm: BootmediaReplaceAlert[mSATA (serial-number-of-boot-device)].
- 运行命令
::> system health alert show
- 或通过 AIQ 门户使用 AutoSupport 进行验证(章节 system-health-alert-persistent.XML )
Node system2-01 Monitor controller Alert ID BootmediaReplaceAlert Alerting Resource mSATA (serial-number-of-boot-device) Subsystem Motherboard Indication Time Sun Aug 16 00:34:48 2020 Perceived Severity Critical Probable Cause hardware_degrading Description Bad sector count in the boot media has reached critical level. Corrective Actions 1. Contact technical support to obtain a new boot device. 2. If possible, perform a takeover of this node and bring the node down for maintenance. 3. Refer to the "Boot media replacement guide for your given hardware platform" to replace the boot device. 4. Update the boot device with the appropriate Data ONTAP version. 5. Bring the storage system online. Possible Effect Upgrading, downgrading, reverting, or applying patches to Data ONTAP can damage the boot device. If the boot device is damaged, the storage system will not boot. Acknowledge false Suppress false Policy BootmediaReplaceAlertPolicy Acknowledger Suppressor Additional Information Vendor ID(in Hex): 8086 Device ID(in Hex): 8d02 Display Name: BootMedia Usbmon Status: present Device State: bad Size(in MB): 114473