跳转到主内容

在接管后,请致电主目录以查看磁盘冗余失败警报

Views:
16
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

  • 8.2.5P5 7- 模式
  • FAS2552

问题描述

  • EMS log show Call home for DISK REDUNDANCY FAILED

[?] Sun Jul 25 09:59:00 CST [Node_B: dsa_disc: shelf.config.tospha:info]: System has transitioned to single path HA attached storage
[?] Sun Jul 25 09:59:00 CST [Node_B: dsa_disc: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED

 

  • 端口 0b 脱机:

slot 0: SAS Host Adapter 0b (PMC-Sierra PM8001 rev. C, SAS, <OFFLINE (hard)>)
        Firmware rev:     01.12.09.00
        Base WWN:      x:xxxxx:xxxxxxx:xx
        Phy State:      [4] Enabled, Rate unknown
                  [5] Enabled, Rate unknown
                  [6] Enabled, Rate unknown
                  [7] Enabled, Rate unknown

 

  • EMS 日志具有 error information about port 0b :

[?] Sun Jul 25 09:43:16 CST [Node_B: pmcsas_intrd_0: sas.port.down:warning]: SAS port "0b" went down.

[?] Sun Jul 25 09:43:47 CST [Node_B: sinai_link_mgr: cf.ic.sbb:debug]: HA interconnect: SBB Compatibility Event. No compatible partner node found. The interconnect device has been disabled.
[?] Sun Jul 25 09:44:02 CST [Node_B: pmcsas_timeout_0: sas.adapter.debug:info]: params: {'debug_string': 'Link down too long ... offlining', 'adapterName': '0b'}
[?] Sun Jul 25 09:44:02 CST [Node_B: pmcsas_timeout_0: sas.link.error:error]: Could not recover link on SAS adapter 0b after 45 seconds. Offlining the adapter.
[?] Sun Jul 25 09:44:02 CST [Node_B: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'pmcsas_asyncd_offline', 'adapterName': '0b'}

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.