マザーボードの故障によるシャーシの電力低下のコールホーム
環境
FAS8200
問題
- に複数のイベントアラートが
chassis power degraded
あります。例:
HA Group Notification from node_name (CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU1.) ERROR
HA Group Notification from node_name (SP HBT MISSED) NOTICE
HA Group Notification from node_name (SP HBT STOPPED) ALERT
- 次のコンソールメッセージが表示されてノードをブートできません。例:
BIOS Version: 11.20
Portions Copyright (C) 2014-2023 NetApp, Inc. All Rights Reserved.
Initializing System Memory ...
Loading Device Drivers ...
Waiting for SP ...
SP failure. Resetting SP from primary FW. This can take a few minutes
Waiting for SP ...
SP failure. Resetting SP from backup FW. This can take a few minutes
Waiting for SP ...
Failed to recover SP
IPMI:Get controller FRU inventory:failed
IPMI:Get midplane FRU 0 inventory:failed
Configuring Devices ...
IPMI PCI Slot Control failed.
CPU = 2 Processor(s) Detected.
Intel(R) Xeon(R) CPU D-1587 @ 1.70GHz (CPU 0)
CPUID: 0x00050664. Cores per Processor = 16
CPU1 (CPU 1)
CPUID: 0x00000000. Cores per Processor = 0
131072 MB System RAM Installed.
SATA (AHCI) Device: SV9MST6D120GLM41NP
Boot Loader version 6.0.17
Copyright (C) 2000-2003 Broadcom Corporation.
Portions Copyright (C) 2002-2023 NetApp, Inc. All Rights Reserved.
BIOS POST Failure(s) detected: SP IPMI failure. Abort AUTOBOOT
- リブート後のサービスプロセッサのデグレードステータス。
- サービスプロセッサのログに複数のセンサー読み取りの問題が記録されています。
- 問題 は、コントローラの交換後も維持されます。