由于端口故障、板载端口上出现CRC错误
问题描述
- CRC错误会在板载端口上累积
::> system node run -node <NODE_NAME> -command ifstat <PORT>
-- interface e0e (6 days, 12 hours, 36 minutes, 51 seconds) --
RECEIVE
Total frames: 1653k | Frames/second: 3 | Total bytes: 357m
Bytes/second: 635 | Total errors: 625 | Errors/minute: 0
Total discards: 0 | Discards/minute: 0 | Multi/broadcast: 2537k
Non-primary u/c: 0 | CRC errors: 625 | Runt frames: 0
Long frames: 0 | Length errors: 0 | Alignment errors: 0
No buffer: 0 | Pause: 0 | Jumbo: 0
- 事件日志中报告了以下错误:
Node-02: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e0e on node Node-02 is reporting a high number of observed CRC errors.
- 更换节点/交换机和缆线上的SFP不会停止错误