跳转到主内容

由于端口故障、板载端口上出现CRC错误

Views:
6
Visibility:
Internal
Votes:
0
Category:
fas-systems<a>2009401678</a>
Specialty:
HW
Last Updated:

 

问题描述

  • CRC错误会在板载端口上累积

::> system node run -node <NODE_NAME> -command ifstat <PORT>

-- interface  e0e  (6 days, 12 hours, 36 minutes, 51 seconds) --
RECEIVE
Total frames:    1653k | Frames/second:     3  | Total bytes:     357m
Bytes/second:    635  | Total errors:    625  | Errors/minute:     0
Total discards:    0  | Discards/minute:    0  | Multi/broadcast:  2537k
Non-primary u/c:    0  | CRC errors:     625  | Runt frames:      0
Long frames:      0  | Length errors:     0  | Alignment errors:   0
No buffer:       0  | Pause:         0  | Jumbo:         0

  • 事件日志中报告了以下错误:

Node-02: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e0e on node Node-02 is reporting a high number of observed CRC errors.

  • 更换节点/交换机和缆线上的SFP不会停止错误