CPU0温度传感器显示故障
适用场景
FAS8200
问题描述
- 报告了错误event log show命令:
::> event log show
 Time                Node             Severity      Event
 ------------------- ---------------- ------------- ---------------------------
 2/12/2025 15:31:01  node_name         ERROR         monitor.temp.unreadable: The controller temperature (CPU0 Temp Margin) is not readable.
- CPU0 Temp传感器在- SP-LATEST-IPMI中显示Failed。
CPU0 Temp Avg            failed            -- C        --          --         -11 C        -1 C    
 InFlow Temp Avg          normal            23 C         0 C         5 C        50 C        55 C    
 OutFlow Temp Avg         normal            37 C         0 C         5 C        65 C        75 C    
 PCI Temp Avg             normal            32 C         0 C         5 C        60 C        70 C    
 Bat Temp Avg             normal            30 C         0 C         5 C        60 C        70 C    
 Amb2 Temp Avg            normal            22 C         0 C         5 C        47 C        52 C    
 Amb1 Temp  Avg           normal            22 C         0 C         5 C        47 C        52 C    
 PSU2 FRU Fan                                OK
 PSU2 FRU Power                              ON
 PSU1 FRU Fan                                OK
 PSU1 FRU Power                              ON
 Fan3 INFO                               FRU_AVAIL
 Fan2 INFO                               FRU_AVAIL
 Fan1 INFO                               FRU_AVAIL
 PSU1 INFO                               FRU_AVAIL
 PSU1 INFO                               FRU_AVAIL
 Fan1                                      GOOD
 Fan2                                      GOOD
 Fan3                                      GOOD
 PSU1                                      GOOD
 PSU2                                      GOOD
 CPU0 Temp Margin         failed            -- C        --          --         -11 C        -1 C    
 In Flow Temp             normal            23 C         0 C         5 C        50 C        55 C    
 Out Flow Temp            normal            37 C         0 C         5 C        65 C        75 C    
 PCI Slot Temp            normal            32 C         0 C         5 C        60 C        70 C    
 Smart Bat Temp           normal            30 C         0 C         5 C        60 C        70 C    
 CPU0 Error                              NORMAL