检测到CN1610风扇警告低速度
适用场景
CN1610
问题描述
CN1610
show tech-support
日志显示"Warning Low speed detected"
errors。show tech-support:
CN1610-1 BSP[envMonTask]: cpu_boxs.c(2128) 159639 %% Setting normal fan speed !
CN1610-1 BSP[envMonTask]: cpu_boxs.c(1751) 159638 %% Requesting normal fan speed !
CN1610-1 BSP[envMonTask]: cpu_boxs.c(1743) 159636 %% Requesting maximum fan speed !
CN1610-1 BSP[envMonTask]: cpu_boxs.c(1646) 159635 %% Fan #1: Warning Low speed detected: 3000 rpm !
CN1610-1 BSP[envMonTask]: cpu_boxs.c(2128) 159628 %% Setting normal fan speed !
CN1610-1 BSP[envMonTask]: cpu_boxs.c(1751) 159627 %% Requesting normal fan speed !
CN1610-1 TRAPMGR[boxs Req]: traputil.c(777) 159626 %% Fan state change alarm: Unit: 1 Fan ID: 1 Event: 3 -Operational
CN1610-1 BOXSERV[boxs Req]: boxs.c(1095) 159625 %% Unit 1 fan 1 OPERATIONAL event (3)occurred.
CN1610-1 TRAPMGR[boxs Req]: traputil.c(777) 159624 %% Fan state change alarm: Unit: 1 Fan ID: 1 Event: 4 - Failure
CN1610-1 BOXSERV[boxs Req]: boxs.c(1095) 159623 %% Unit 1 fan 1 FAILURE event (4) occurred.
CN1610-1 BSP[envMonTask]: cpu_boxs.c(1743) 159621 %% Requesting maximum fan speed !
CN1610-1 BSP[envMonTask]: cpu_boxs.c(1716) 159620 %% Detected 3 fans operational !
CN1610-1 BSP[envMonTask]: cpu_boxs.c(1622) 159619 %% Fan #1: Critical Low speed detected: 2640 rpm
Fans:
Unit Fan Description Type Speed Duty level State
---- --- -------------- --------- ------------- ------------- --------------
1 1 Fan-1 Removable 6180 50% Operational
1 2 Fan-2 Removable 6240 50% Operational
1 3 Fan-3 Removable 6420 50% Operational
1 4 Fan-4 Removable 6300 50% Operational
Power Modules:
Unit Power supply Description Type State
---- ------------ ---------------- ---------- --------------
1 1 Internal AC-1 Removable Operational
1 2 Internal AC-2 Removable Operational