由于两个集群端口均关闭,发生 CLAM 接管
适用场景
- ONTAP 9
- 连接性、流畅性和可用性监控器(VANM)
问题描述
- 由于节点的两个集群端口均发生故障,CLAM 出现混乱
PANIC: Received PANIC packet from partner, receiving message is (Coredump and takeover initiated because Connectivity, Liveliness and Availability Monitor (CLAM) has determined this node is out of quorum.) in SK process gop_eq_thread on release 9.9.1P15 (C) on Sun Jun 22 02:24:18 JST 2025
[?] Sun Jun 22 02:23:19 +0900 [NODE: mgmt_port_link_status_poll: netif.linkDown:info]: Ethernet e0a: Link down, check cable.
[?] Sun Jun 22 02:23:19 +0900 [NODE: mgmt_port_link_status_poll: netif.linkDown:info]: Ethernet e0b: Link down, check cable.
- 集群端口自动恢复。
slot 0: 10 Gigabit Ethernet Controller IX5-SFP+
e0a MAC Address: d0:39:ea:1d:c4:0a (auto-10g_twinax-fd-up)
SFP Vendor: CISCO-JPC
SFP Part Number: P3057U305000-1
SFP Serial Number: JPC233600S8-CH1
e0b MAC Address: d0:39:ea:1d:c4:0b (auto-10g_twinax-fd-up)
SFP Vendor: CISCO-JPC
SFP Part Number: P3057U305000-1
SFP Serial Number: JPC233600YL-CH1
Device Type: X550EM
Firmware Version: 1.13-7.1