跳转到主内容

出现多个磁盘的一些校验错误后、两个SAS端口脱机

Views:
11
Visibility:
Public
Votes:
0
Category:
aff-series<a>2009468999</a>
Specialty:
hw
Last Updated:

适用场景

  • SAS磁盘架连接
  • X357_S163A3T8ATE NA54驱动器
  • MetroCluster IP

问题描述

  • 报告了3个特定驱动器的校验和错误。
  • 校验和错误已在擦除期间修复。
  • 由于3个驱动器上的校验和验证失败、主SAS适配器脱机。
  • 由于问题描述 相同、二级SAS适配器脱机。
  • 示例

[node_name: raidio_thread: raid_read_cksum_embed_1:notice]: params: {'owner': '', 'disk_info': 'Disk /aggregate/plex0/rg0/0a.01.1 Shelf 1 Bay 1 [NETAPP   X357_S163A3T8ATE NA54]...
[node_name: raidio_thread: raid_rg_readerr_repair_cksum_error_1:notice]: params: {'disk_rpm': 'N/A', 'vendor': 'NETAPP  ', 'firmware_revision': 'NA54', 'shelf': '1', 'disk_info': 'Disk /aggregate/plex0/rg0/0a.01.1 Shelf 1 Bay 1 [NETAPP   X357_S163A3T8ATE NA54] ...
...
[node_name: disk_admin: disk.checksum.offlineAdapter:alert]: Adapter 0a taken offline due to checksum verification failure on multiple disks. Keep the adapter offline and contact Contact NetApp technical support. for assistance.
[node_name: disk_admin: callhome.hba.failed:EMERGENCY]: Call home for Write Verification Error: Port 0a Failed. Keep the adapter offline and contact NetApp technical support for assistance.
[node_name: asd_asyncd_0: sas.adapter.offline:info]: SAS adapter 0a is now offline.

[node_name: raidio_thread: raid_read_cksum_embed_1:notice]: params: {'owner': '', 'disk_info': 'Disk /aggregate/plex0/rg0/0b.01.1 Shelf 1 Bay 1 [NETAPP   X357_S163A3T8ATE NA54]...
[node_name: raidio_thread: raid_rg_readerr_repair_cksum_error_1:notice]: params: {'disk_rpm': 'N/A', 'vendor': 'NETAPP  ', 'firmware_revision': 'NA54', 'shelf': '1', 'disk_info': 'Disk /aggregate/plex0/rg0/0b.01.1 Shelf 1 Bay 1 [NETAPP   X357_S163A3T8ATE NA54] ...
[node_name: disk_admin: disk.checksum.offlineAdapter:alert]: Adapter 0b taken offline due to checksum verification failure on multiple disks. Keep the adapter offline and contact Contact NetApp technical support. for assistance.
[node_name: disk_admin: callhome.hba.failed:EMERGENCY]: Call home for Write Verification Error: Port 0b Failed. Keep the adapter offline and contact NetApp technical support for assistance.
[node_name: asd_asyncd_0: sas.adapter.offline:info]: SAS adapter 0b is now offline.

[node_name: config_thread: callhome.checksum.multiple:alert]: Call home for CHECKSUM ERROR (multiple disks)

  • 更换控制器后、问题描述 仍会保留。
  • 问题描述 仍使用外部卡SAS端口
  • 擦除完成后、问题描述 仍会保留

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.