适用场景

  • ONTAP 9
  • AFF A400、FAS9300、FAS8700
  • BMC 13.8x, 13.7Px

问题描述

  • 服务处理器未响应:
::> sp show
                IP      Firmware              
Node      Type Status    Configured  Version  IP Address        
------------- ---- ----------- ------------ --------- -------------------------
node-01    BMC  online    true     13.7    1.2.3.4        
Error: show failed: Timeout: Operation "sp_system_view_iterator::get_imp()" took longer than 25 seconds to complete [from mgwd on node "node_name-01" (VSID: -1) to servprocd at 127.0.0.1]
  • 事件日志中报告了多个servprocd和TCP端口935错误

[node-01: servprocd: kern.vm.mmap.return:notice]: mmap(2) by servprocd (pid 6180) for size 2101248 failed: VMEM limit exceeded, limit 1099689656, error 12.

[node-01: servprocd: ucore.panicString:error]: 'servprocd: Call to pthread_create() failed with error: Resource temporarily unavailable, raising SIGABRT(6) at RIP 0x807ba483a (pid 6419, uid 0, timestamp 1696133989)'

[node-01: spmd: spm.servprocd.process.exit:alert]: Service processor daemon (servprocd) with ID 6419 exited as a result of Virtual size limit exceeded. This server will attempt to restart.

[node-01: kernel: bsdsocket.queueLimit.reached:error]: Number of connection requests for the socket bound to port 935 having the IP address * has reached the limit of 1536 connections. The socket uses TCP protocol. This event has occurred 1 times since the last warning.

  • 的输出 sysconfig -a 显示:

::> system node run -node <node> -command sysconfig -a

Service Processor      Status: Unknown
Firmware Version:  (null)
Mgmt MAC Address:  (null)
Ethernet Link:    down
****FAILED : smf_sp_network_status_get for IPv4
IPv4 configuration:     Disabled
****FAILED : smf_sp_network_status_get for IPv6
IPv6 configuration:     Disabled

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.