ONTAP 升级后,BMC 固件更改为 15.92 或 15.93
适用于
- ONTAP 9
- AFF A250
- 基板管理控制器(BMC)
问题描述
- ONTAP 升级后,一个节点的 BMC 固件版本显示为 15.92 或 15.93:
Service Processor      Status: Online
   Firmware Version:  15.92 
   Mgmt MAC Address:   d0:39:ea:49:6d:d3
   Ethernet Link:    up, 1Gbps
   Using DHCP:      no
- 合作伙伴节点已正确升级到与 ONTAP 捆绑的 BMC 固件:
Cluster::> system service-processor show
                 IP       Firmware
 Node      Type Status    Configured   Version   IP Address
 ------------- ---- ----------- ------------ --------- -------------------------
 Node-01     BMC  online      true     15.10   10.X.XXX.3
 Node-02     BMC  online      true     15.92   10.X.XXX.4
 2 entries were displayed.
- 在 AutoSupport 的 SP-MGMT-MLOG-TXT.GZ部分中可以看到以下事件:
[kern_servprocd:info:6467] 0x808ad2700: 0: NOTICE: Servprocd::SpUpdate: update: BMC update has been successfully triggered.
 [kern_servprocd:info:6467] 0x808ad2700: 0: NOTICE: Servprocd::SpUpdate: lookup_bmc_updt_str: BMC update - Image flash in progress.(0x8)
 [kern_servprocd:info:6467] 0x80a028e00: 8803e8000009f720: ERR: Servprocd::CLI: get_bmc_boot_image: Failed to get boot image for BMC
 [kern_servprocd:info:6467] 0x808ad2700: 0: NOTICE: Servprocd::SpUpdate: monitorUpdate: Waiting for BMC update to complete. Monitor count=(3), sleep 30 seconds...
 [kern_servprocd:info:6467] 0x808ad2700: 0: ERR: Servprocd::SpUpdate: servprocd_cpmi_get_fw_update_info: cpmi_get_fw_update_info(0x10) Failed.
 [kern_servprocd:info:6467] 0x808ad2700: 0: ERR: Servprocd::SpUpdate: monitorUpdtPrgrs: unable to get firmware update progress.
- 重新启动受影响节点的 BMC 不会将 BMC 更新为正确版本。