适用于

  • AFF A900/FAS9500
  • ONTAP 9
  • BMC 固件 16.8

问题

  • 将 AFF A900 或 FAS9500 升级到 BMC 固件 16.8 后,某些系统可能会报告 PSU3 和 PSU4 故障
    • 示例
          EMS 日志:
      Wed Apr 15 14:24:25 -0700 [rno2-cdot33-05: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 3 is degraded: PSU3 AC In Volt is Unreadable Wed Apr 15 14:24:26 -0700 [rno2-cdot33-05: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 3 is degraded: PSU3 AC In Curr is Unreadable Wed Apr 15 14:24:26 -0700 [rno2-cdot33-05: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 3 is degraded: PSU3 12V Out Volt is Unreadable Wed Apr 15 14:24:26 -0700 [rno2-cdot33-05: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 3 is degraded: PSU3 12V Out Curr is Unreadable
      Wed Apr 15 22:03:35 -0700 [rno2-cdot33-06: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 4 is degraded: PSU4 AC In Volt is Unreadable Wed Apr 15 22:03:35 -0700 [rno2-cdot33-06: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 4 is degraded: PSU4 AC In Curr is Unreadable Wed Apr 15 22:03:35 -0700 [rno2-cdot33-06: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 4 is degraded: PSU4 12V Out Volt is Unreadable Wed Apr 15 22:03:35 -0700 [rno2-cdot33-06: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 4 is degraded: PSU4 12V Out Curr is Unreadable

      Autosupport 中的 SP-Latest-IPMI 部分(以下是受影响的特定传感器。合作伙伴 PSU4 的输出相同)

      PSU3_Status | 0x0 | discrete | AC OK | na | na | na | na PSU3_12V_OP_I | na | Amps | na | 0.000 | 0.000 | 140.000 | 144.000 PSU3_12V_OP_V | na | Volts | na | 10.980 | 11.400 | 12.900 | 13.500 PSU3_AC_IP_I | na | Amps | na | na | na | 14.000 | 14.980 PSU3_AC_IP_V | na | Volts | na | 88.000 | 90.000 | 255.000 | 255.000 PSU3_Fault | na | discrete | na | na | na | na | na

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.