跳转到主内容

检测到 BIOS POST 故障:SP IPMI 故障

Views:
6
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
HW
Last Updated:

适用于

  • AFF 和 FAS 平台

问题描述

  • 机箱中的一个节点锁定 I2C 总线
  • 未检测到合作伙伴的心跳后启动接管。示例

[node_name : cf_main: cf.fsm.takeover.noHeartbeat:alert]: Failover monitor: Takeover initiated after no heartbeat was detected from the partner node.
[node_name : monitor: monitor.globalStatus.critical:EMERGENCY]: This node has taken over .

  • 传感器不再可读
  • 停机节点引导失败。示例
 Failed to recover SP IPMI:Get controller FRU inventory:failed IPMI:Get midplane FRU 0 inventory:failed Configuring Devices ... IPMI PCI Slot Control failed .... BIOS POST Failure(s) detected: SP IPMI failure. Abort AUTOBOOT 
  • 由于I2C总线锁定,多个传感器无法读取。示例

[node_name : env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Temperature is Unreadable
[node_name : env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Current is Unreadable
[node_name : env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Fan1 Speed is Unreadable
[node_name : env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Fan2 Speed is Unreadable
[node_name : env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Over Temp is Unreadable
[node_name : env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Over Volt is Unreadable
[node_name : env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Over Curr is Unreadable
[node_name : env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 InPower Monitor is Unreadable
[node_name : cphmd: hm.alert.raised:alert]: Alert Id = CriticalFanFruFaultAlert , Alerting Resource = xxxx raised by monitor chassis
[node_name : env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Over Curr is Unreadable
[node_name : env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Crest Factor is Unreadable
[node_name : env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 InPower Monitor is Unreadable
[node_name : env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Over Temp is Unreadable

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.