已取消自动关闭序列
适用场景
- FAS8300
- FAS8700
- BMC FW 13.5
问题描述
- 系统生成以下AutoSupport警报
Call home for BATTERY (wrong charge) WARNING.
- EMS日志中会显示以下消息
[Node-01: env_mgr: nvmem.battery.wrongCharge:alert]: The NVMEM battery charger is charging the battery even though the battery is not requesting to be charged. To prevent data loss, the system will shut down in 24 hours.
[Node-01: env_mgr: callhome.battery.warning:alert]: Call home for BATTERY (wrong charge) WARNING.
[Node-01: env_mgr: nvmem.battery.normalCharge:notice]: The NVMEM battery charging status is normal.
[Node-01: env_mgr: monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled.
- BMC固件已升级到13.5
- 不再显示NVMEM电池消息
- 仍会记录以下消息:
Sun Aug 22 08:46:18 +0200 [Node-01: env_mgr: monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled.
Sun Aug 22 09:46:19 +0200 [Node-01: env_mgr: monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled.
Sun Aug 22 10:46:19 +0200 [Node-01: env_mgr: monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled
。