跳转到主内容

更新磁盘认证包后自动分区磁盘

Views:
5
Visibility:
Public
Votes:
0
Category:
disk-drives<a>ADPv2</a><a>DQP</a><a>2008918410</a>
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9.5P6
  • ADPV2
  • 磁盘认证包( DQP )更新
  • 磁盘固件更新

问题描述

完整 SSD 备用磁盘会自动分区,无需手动操作。示例

  • 之前: 

Pool0 spare disks
RAID Disk   Device    HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
---------   ------    ------------- ---- ---- ---- ----- --------------   --------------
spare     0a.02.14   0a   2   14  SA:B   0   SSD   N/A 3662580/7500964352 3662830/7501476528 (not zeroed)

Pool0 spare disks
RAID Disk   Device    HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
---------   ------    ------------- ---- ---- ---- ----- --------------   --------------
spare    0a.02.22  0a   2   22  SA:A   0   SSD   N/A 3662580/7500964352 3662830/7501476528 (not zeroed)

  • 之后:

Pool0 spare disks
RAID Disk   Device    HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
---------   ------    ------------- ---- ---- ---- ----- --------------   --------------
spare    0a.02.22P1 0a   2   22  SA:B   0   SSD   N/A 1819289/3725904896 1819297/3725921280 (not zeroed)
spare     0a.02.14   0a   2   14  SA:B   0   SSD   N/A 3662580/7500964352 3662830/7501476528 (not zeroed)

Pool0 spare disks
RAID Disk   Device    HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
---------   ------    ------------- ---- ---- ---- ----- --------------   --------------
spare    0a.02.22P3 0a   2   22  SA:A   0   SSD   N/A 23956/49062912   23964/49079296 (not zeroed)
spare    0a.02.22P2 0a   2   22  SA:A   0   SSD   N/A 1819289/3725904896 1819297/3725921280 (not zeroed)

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.