跳转到主内容

AFF-C30 系统上的琥珀色 LED 灯和"Bat_Full_Cap: Current Sensor 95 LNC/LCR"错误

Views:
41
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • AFF C30
  • BMC 固件 19.1P1

问题描述

  • 系统发生 panic 或意外接管事件。
  • 控制器背面的琥珀色 LED 亮起。
  • system health alert show command 不显示任何活动警报。
  • system controller service-event show 显示与 NVRAM 电池相关的事件。

::> system controller service-event show
Node ID Event Location Event Description
---------------- --- ---------------------------------- ----------------------
NodeA 1 NV Battery on Controller B Bat_Full_Cap: Current Sensor 95 LNC
NodeB 2 NV Battery on Controller B Bat_Full_Cap: Current Sensor 95 LCR

  • system controller show 报告状态为 OK。

::> system controller show
Controller Name    System ID    Serial Number    Model   Status
------------------------- ------------- ----------------- -------- -----------
NodeA           539037035    ******    AFF-C30  ok
NodeB           539037065    ******    AFF-C30  ok
2 entries were displayed.

  • 重新启动控制器不会解决琥珀色 LED 或警报情况。
  • SP-LATEST-IPMI 日志显示Current Sensor 95 LNC/LCR错误。
hsamcmd --fault-show-all =============================== tag origin fld fault reason count time ---- ------- ---- ------------- ------ ----- 1 bmc /chassis-1/controller-a/nvbatt-1 Bat_Rem_Cap: Current Sensor 94 LNC 1 2 bmc /chassis-1/controller-a/nvbatt-1 Bat_Rem_Cap: Current Sensor 94 LCR 1 3 bmc /chassis-1/controller-a/nvbatt-1 Bat_Full_Cap: Current Sensor 95 LNC 1 4 bmc /chassis-1/controller-a/nvbatt-1 Bat_Full_Cap: Current Sensor 95 LCR 1 5 bmc /chassis-1/controller-a/nvbatt-1 Bat_Dstg_Cycles: Battery Sensor 99 Fault 2

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.