跳转到主内容

更换磁盘后琥珀色 LED 指示灯保持亮起

Views:
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • 所有 FAS/AFF 平台。
  • ONTAP 9

问题描述

  • 磁盘更换后,琥珀色 LED 亮起
  • 设备最大链路速度仅显示 8.0

Shelf name:   0x.shelf10
Shelf id:    10
Channel:     0x
Module:     B
Shelf UID:   XXXXXXXXXXXXXX
Shelf S/N:    XXXXXXX
Term switch:   N/A
Shelf state:   ONLINE
Module state:  OK

         Device     Port      Negotiated   Medium     Device     Port      Negotiated   Received
Disk   Port    Max Link    Max Link    Link      Max Link    Max Lane    Max Lane    Lane      Error     Bad TLP    Bad DLLP    Uncorrectable  Correctable
Id    State    Speed     Speed     Speed      Speed     Width     width      width     Count     Count     Count     Errors      Errors
         (GT/s)     (GT/s)     (GT/s)     (GT/s)
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
[   0] OK     16.0      8.0      8.0       8.0      2       2       2        0       0       0       0        0
[   1] OK     16.0      8.0      8.0       8.0      2       2       2        0       0       0       0        0
[   2] OK     16.0      8.0      8.0       8.0      2       2       2        0       0       0       0        0
[   3] OK     16.0      8.0      8.0       8.0      2       2       2        0       0       0       0        0
[   4] OK     16.0      8.0      8.0       8.0      2       2       2        0       0       0       0        0
[   5] OK     16.0      8.0      8.0       8.0      2       2       2        0       0       0       0        0
[   6] OK     16.0      8.0      8.0       8.0      2       2       2        0       0       0       0        0
[   7] OK     16.0      8.0      8.0       8.0      2       2       2        0       0       0       0        0
[   8] OK     8.0      8.0      8.0       8.0      2       2       2        0       0       0       0        0      
[   9] OK     16.0      8.0      8.0       8.0      2       2       2        0       0       0       0        0

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.