适用场景

  • FAS2552
  • FAS2554
  • ONTAP 8.3.2P5

问题描述

  • 集群端口e0e/e0f会同时关闭或关闭链路。

示例:

[ltm_services: snmp.link.down:info]: Interface 3 is down.
[ltm_services: netif.linkDown:info]: Ethernet e0e: Link down, check cable.
[pmcsas_timeout_0: sas.adapter.debug:info]: params: {'debug_string': 'Link down too long ... offlining', 'adapterName': '0b'}
[ltm_services: snmp.link.down:info]: Interface 4 is down.
[ltm_services: netif.linkDown:info]: Ethernet e0f: Link down, check cable.

 

如果端口未恢复、并且已启用连接、则显示实时性和可用性监控(CLAL)。

  • 其中一个节点上将出现“超出法定人数”紧急情况。
示例:
 
PANIC : Received PANIC packet from partner, receiving message is (Coredump and takeover initiated because Connectivity, Liveliness and Availability Monitor (CLAM) has determined this node is out of quorum.
 
  • 将接管出现紧急情况的节点、正常运行的节点将为所有数据提供服务。
如果端口未恢复、并且未启用连接、则显示实时性和可用性监控(CLAL)。
  • 将不会进行接管操作、并且两个节点都将超出法定数量。两个节点都不会提供数据。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 