由于环境原因关闭(电池不存在), AFF A700 关闭

Views:
35
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

  • AFF A700
  • FAS9000
  • 降级控制器电源模块( DCPM ),其中包含 NVRAM10 电池

问题描述

  • 由于电池错误,系统关闭
  • 从 EMS :
 Jan 21 01:45:15 [node-01:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (not present) CRITICAL. Fri Jan 21 09:45:32 GMT [nvram.hw.initWarn:WARNING]: NVRAM hardware initialization: Failed to get Battery FRU info. Jan 21 01:46:20 [node-01:nvram.battery.not.present:EMERGENCY]: The NVRAM battery is not present. To prevent data loss, the system will shut down in 5 minutes. Jan 21 01:51:20 [node-01:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery not present) Terminated . Uptime: 169d11h5m58s System powering down... 
 
  • system sensors show 服务处理器:

DCPM:

Bat_Status       | 0x0        | discrete   | Absent     | na        | na        | na        | na
Bat_Ambient_1    | na         | degrees C  | na         | 0.000     | 3.000     | 47.000    | 52.000
Bat_Ambient_2    | na         | degrees C  | na         | 0.000     | 3.000     | 47.000    | 52.000
Bat_Charge_Curr  | na         | Amps       | na         | na        | na        | 5.500     | 6.000
Bat_Charge_Volt  | na         | Volts      | na         | na        | na        | 8.350     | 8.400
Bat_Curr         | na         | Amps       | na         | -0.100    | -0.050    | 2.500     | 3.000
Bat_Cycle_Count  | na         | cycles     | na         | na        | na        | na        | na
Bat_Design_Cap   | na         | Amps*hour  | na         | 0.000     | 0.000     | 6.375     | 6.375
Bat_Dstg_Cycles  | na         | cycles     | na         | 2.000     | 5.000     | na        | na
Bat_Full_Cap     | na         | Amps*hour  | na         | 2.000     | 2.200     | 4.750     | 5.000
Bat_Initial_Fcc  | na         | Amps*hour  | na         | 2.000     | 2.200     | 4.750     | 5.000
Bat_Rem_Cap      | na         | Amps*hour  | na         | 0.250     | 0.500     | 4.750     | 5.000
Bat_Temp         | na         | degrees C  | na         | -5.000    | 0.000     | 55.000    | 60.000
Bat_Volt         | na         | Volts      | na         | 6.000     | 6.500     | 8.300     | 8.500
 
  • events all 服务处理器:
 SP node-01> events all Record 1: Fri Jan 21 11:12:07.966816 2022 [SP.notice]: No response from battery charger Record 2: Fri Jan 21 11:12:08.142235 2022 [SP.notice]: No response from battery charger Record 3: Fri Jan 21 11:12:08.421014 2022 [SP.notice]: No response from battery charger Record 4: Fri Jan 21 11:12:08.538567 2022 [SP.notice]: No response from battery charger Record 5: Fri Jan 21 11:12:08.703007 2022 [SP.notice]: No response from battery charger Record 6: Fri Jan 21 11:12:08.918484 2022 [SP.notice]: No response from battery charger Record 7: Fri Jan 21 11:12:09.097875 2022 [SP.notice]: No response from battery charger Record 8: Fri Jan 21 11:12:09.314864 2022 [SP.notice]: No response from battery charger Record 9: Fri Jan 21 11:12:09.486175 2022 [SP.notice]: No response from battery charger 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.