使用 SFP 的未使用端口上的 AFF A400 端口错误
适用场景
- AFF A400
- 10/25 Gb/ 秒网络适配器
- 未使用的以太网端口
问题描述
Sysconfig -A
端口显示 SFP 的链路已启动或摆动,但未插入缆线:
slot 0: 10G/25G Ethernet Controller CX5-Mezz
e0e MAC Address: d0:22:ef:97:00:0d (auto-25g_sr-fd-up)
SFP Vendor: AVAGO
SFP Part Number: AFBR-725SMZ-NA1
SFP Serial Number: AD2016G02TZ
EMS 日志
vifmgr.port.monitor.failed: The "link_flapping" health check for port e0e (node node-01) has failed. The port is operating in a degraded state.
- 端口可报告 CRC 错误:
EMS
[node-01: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e0f on node node-01 is reporting a high number of observed hardware errors, possibly CRC errors.
- ifstat
::> system node run -node <node> -command ifstat -a
RECEIVE
Total frames: 0 | Frames/second: 0 | Total bytes: 0
Bytes/second: 0 | Total errors: 66920 | Errors/minute: 0
Total discards: 0 | Discards/minute: 0 | Multi/broadcast: 0
Non-primary u/c: 0 | Errored frames: 0 | Unsupported Op: 0
CRC errors: 66918 | Runt frames: 0 | Fragment: 66914