AFF A250无法启动、并且在L2 watchdog重置后无响应
适用场景
- AFF A250
- FAS500f
问题描述
- 由于L2监视器重置、节点发生接管:
- EMS:
Mon Nov 14 05:20:27 +0000 [NetApp-01: cf_hwassist: cf.hwassist.takeoverTrapRecv:notice]: hw_assist: Received takeover hw_assist alert from partner(NetApp-02), system_down because l2_watchdog_reset.
Mon Nov 14 05:20:28 +0000 [NetApp-01: cf_hwassist: cf.hwassist.takeoverTrapRecv:notice]: hw_assist: Received takeover hw_assist alert from partner(NetApp-02), system_down because reset_via_sp.
- BMC:
11/14/2022 | 05:20:24 | Voltage #0x29 | Lower Non-critical going low
11/14/2022 | 05:20:24 | Voltage #0x29 | Lower Critical going low
11/14/2022 | 05:20:25 | Watchdog 2 #0x0f | Timer interrupt | Asserted
11/14/2022 | 05:20:26 | Watchdog 2 #0x0f | Hard reset | Asserted
11/14/2022 | 05:20:27 | Unknown #0x51 | State Asserted
11/14/2022 | 05:21:26 | Power Unit #0x60 | Power off/down | Asserted
11/14/2022 | 05:24:22 | Voltage #0x2a | Lower Non-critical going low
11/14/2022 | 05:24:22 | Voltage #0x2a | Lower Critical going low
11/14/2022 | 05:29:19 | Power Unit #0x60 | Power cycle | Asserted
- 受损节点无法启动
- BMC可访问