由于检测到错误的充电器电路,节点关闭
适用于
- ONTAP 9
- AFF A400,C400
- ASA A400,C400
- FAS8300,8700
问题
- AutoSupport 警报 -
HA Group Notification (BATTERY (wrong charge with a bad charger)) ALERT
- EMS 日志:
Mon May 12 19:12:04 +0200 [node1: env_mgr: nvmem.battery.capLowWarn:error]: The NVMEM battery capacity is below normal (3 cycles).Mon May 12 20:00:00 +0200 [node1: statd: monitor.shutdown.nvramLowBattery.pending:alert]: NVRAM battery is dangerously low. Halting system in 1 hour. Replace the battery immediately!Mon May 12 20:12:04 +0200 [node1: env_mgr: nvmem.battery.capLowWarn:error]: The NVMEM battery capacity is below normal (3 cycles).Mon May 12 21:00:00 +0200 [node1: statd: monitor.nvramLowBattery.notice:notice]: If the NVRAM battery is dangerously low, the system shuts down automatically every 24 hours to encourage you to replace it. If you reboot the system it will run for another 24 hours before shutting down.Mon May 12 21:00:22 +0200 [node1: shutdown_thread0: kern.shutdown:notice]: System shut down because : "NVRAM BATTERY FAILURE".- 充电器错误:
Fri May 16 17:14:31 +0200 [node1: env_mgr: nvmem.battery.chgrFailed:error]: The NVMEM battery charger is disabled because a bad charger circuit is detected.- 无 EMS 警报
nvmem.battery.capLowCrit和nvmem.battery.fccLowCrit - 更换后,系统无法识别新的 NVRAM 电池
- 系统运行在固定版本的 CONTAP-268265