AF-A320 缺少磁盘架 NS224NSM100 上一个模块的路径
适用场景
- AFF A320
- NS224
问题描述
- 节点在
storage check-cables
输出中缺少指向磁盘架模块的路径。示例:
cluster::> storage check-cables
[Error: DualPathToNSM] There are two ports cabled from node "node_name" to topmodule (A) on Shelf with SN serial_number:
Port e0b on node is connected to port e0b of top module (A) on Shelf with SN serial_number.
Port e0e on node is connected to port e0a of top module (A) on Shelf with SN serial_number.
One of these cables should be removed.
[Error: MissingRedundantPath] Node "node_name" is missing a path to bottom module (B) on Shelf with SN serial_number.