環境

  • AFF-A250
  • ベースボード管理コントローラ(BMC)ファームウェア15.7以下

問題

  • 予期しないノード停止。例:

[node_name: spmgrd: sp.heartbeat.stopped:error]: Have not received a IPMI heartbeat from the Service Processor (SP) in last 600 seconds.
[node_name: spmgrd: callhome.sp.hbt.missed:notice]: Call home for SP HBT MISSED
[node_name: spmgrd: callhome.sp.hbt.stopped:alert]: Call home for SP HBT STOPPED
[node_name: env_mgr: sp.ipmi.lost.shutdown:EMERGENCY]: SP heartbeat stopped and cannot be recovered. To prevent hardware damage and data loss, the system will shut down in 10 minutes.
[node_name: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (System reboot to recover the BMC)
[node_name: mgwd: mgwd.notify.halt.result:info]: MGWD able to notify CLAM on its HA partner node that this node is undergoing a planned shutdown (reason: E). Error: -

  • BMCイベントログは、IPMIコールドリセットと複数のバス修正可能なエラーを示しています。
BMC node_name> system log sel
3e1 | 03/08/2023 | 16:09:46 | Critical Interrupt #0x31 | Bus Correctable error | Asserted
3e2 | 03/08/2023 | 16:09:46 | Critical Interrupt #0x31 | Bus Correctable error | Asserted
...
3f1 | OEM record f2 | IPMI cold reset
3f2 | OEM record f2 | Pilot Software reset
  • またはFPGAによるBMCリセット: 
 1c9 | OEM record f2 | FPGA pull BMC whole reset
 1ca | OEM record f2 | Pilot AC cycle
  •  シリアルコンソールポートを介しても、ノードのBMCにアクセスできない場合があります。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.