AFF-A250 节点因断电而关闭
适用场景
- AF-A250
- BMC FW 15.4.
问题描述
- AF-A250节点已关闭、日志指示问题描述已启动
1a2 | 01/01/2000 | 00:00:37 | Battery #0x4f | State Deasserted 1a3 | 01/01/2000 | 00:00:21 | Battery #0x4a | State Deasserted 1a4 | 01/01/2000 | 00:00:21 | Battery #0x4b | State Asserted 1a5 | 01/01/2000 | 00:00:22 | Battery #0x4c | State Asserted 1a6 | 01/01/2000 | 00:00:22 | Battery #0x4d | State Deasserted 1a7 | 01/01/2000 | 00:00:22 | Other FRU #0x50 | 1a8 | 01/01/2000 | 00:00:22 | Other FRU #0x50 | 1a9 | 01/01/2000 | 00:00:22 | Other FRU #0x50 | 1aa | 01/01/2000 | 00:00:22 | Other FRU #0x50 | 1ab | 01/01/2000 | 00:00:28 | Power Supply #0x20 | Presence detected | Asserted 1ac | 01/01/2000 | 00:00:28 | Power Supply #0x25 | Presence detected | Asserted 1ad | 01/01/2000 | 00:00:37 | Battery #0x4f | State Deasserted 1ae | 01/01/2000 | 00:05:37 | Power Unit #0x60 | Power cycle | Asserted 1af | 01/01/2000 | 00:05:55 | System Event #0xff | Timestamp Clock Sync | Asserted 1b0 | 12/21/2021 | 02:40:22 | System Event #0xff | Timestamp Clock Sync | Asserted 1b1 | 12/21/2021 | 02:41:32 | Power Unit #0x60 | Power off/down | Asserted
- 配对节点未显示电源警报
- 关闭节点后、需要手动启动ONTAP
- 启动ONTAP节点后、从BMC看到电压警报
1bd | 01/02/2022 | 19:24:46 | Voltage #0x30 | Upper Non-critical going high 1be | 01/02/2022 | 19:26:54 | Voltage #0x30 | Upper Non-critical going high 1bf | 01/02/2022 | 23:16:24 | Voltage #0x30 | Upper Non-critical going high 1c0 | 01/02/2022 | 23:18:33 | Voltage #0x30 | Upper Non-critical going high 1c1 | 01/03/2022 | 06:14:46 | Voltage #0x30 | Upper Non-critical going high 1c2 | 01/03/2022 | 06:16:54 | Voltage #0x30 | Upper Non-critical going high