报告了外部磁盘架的 ACP 错误
适用场景
IOM12磁盘架
问题描述
EMS.log
报告两个磁盘架ACP模块均出现故障。示例:
ses.status.ACPError:alert]: DS224-12 (S/N XXXXXXXXXXXXXXX) shelf 24 on channel 9c ACP Processor error for SAS shelf ACP processor 1: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top left, on shelf module A.
ses.status.ACPError:alert]: DS224-12 (S/N XXXXXXXXXXXXXXX) shelf 24 on channel 9c ACP Processor error for SAS shelf ACP processor 2: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top right, on shelf module B.
monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 1b. Check fans, power supplies, disks, and temperature sensors.
callhome.shlf.fault:error]: Call home for SHELF_FAULT
- CLI 会报告两个 ACP 模块的严重状态:
Cluster::> system node run -node <node name>
-command storage show fault -v
Enclosure Status: critical
Channel: 1b
Shelf: 24
Shelf Type: DS224-12
Product Serial Number: XXXXXXXXXXXXXXX
Module Type: IOM12
Vendor Unique Element 85-IOM12: (ACP)
Element Status Status Bytes Status Descriptions
1 [IOM12 A] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL
2 [IOM12 B] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL
- 禁用/重新启用ACP后、问题描述仍会保留
- 重新拔插磁盘架模块后、问题描述仍然存在
- 更换磁盘架模块后、问题描述仍会保留
- 磁盘架重新启动后、问题描述仍会保留