EMS.log报告两个盘架 ACP 模块均出现故障。示例:
ses.status.ACPError:alert]: DS224-12 (S/N XXXXXXXXXXXXXXX) shelf 24 on channel 9c ACP Processor error for SAS shelf ACP processor 1: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top left, on shelf module A.ses.status.ACPError:alert]: DS224-12 (S/N XXXXXXXXXXXXXXX) shelf 24 on channel 9c ACP Processor error for SAS shelf ACP processor 2: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top right, on shelf module B.monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 1b. Check fans, power supplies, disks, and temperature sensors.callhome.shlf.fault:error]: Call home for SHELF_FAULT- CLI 报告两个 ACP 模块均处于严重状态:
Cluster::> system node run -node <node name> -command storage show fault -vEnclosure Status: criticalChannel: 1bShelf: 24Shelf Type: DS224-12Product Serial Number: XXXXXXXXXXXXXXXModule Type: IOM12Vendor Unique Element 85-IOM12: (ACP)Element Status Status Bytes Status Descriptions1 [IOM12 A] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL2 [IOM12 B] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL- 禁用/重新启用 ACP 后问题仍然存在
- 重新拔插磁盘架模块后问题仍然存在
- 更换磁盘架模块后问题仍然存在
- 磁盘架重启电源后问题仍然存在