e1a或e1b端口关闭
适用于
- AFF A800
- FAS2820
问题
- 集群 e1a 或 HA 互连 e1b 端口在
::> system node run -node node_name -command sysconfig -a输出中已关闭。示例:
slot 1: Dual 40/100G Ethernet T62100-CR
e1a MAC Address: 00:07:43:51:03:00 (auto-unknown-fd-down)
e1b MAC Address: 00:07:43:51:03:08 (auto-unknown-fd-down)
Device Type: T6 2
Firmware Version: 1.24.12.0
Part Number: 110122860B1
Hardware Revision: 0
Serial Number: PT09190900
- ONTAP 事件消息系统 (EMS) 报告。示例:
Mon Apr 14 18:48:11 +0900 [node_name: intr: netif.linkDown:info]: Ethernet e0a: Link down, check cable.
或netif.linkDown: Ethernet a0b: Link down, check cable.netif.linkDown: Ethernet e1b: Link down, check cable.vifmgr.portdown: A link down event was received on node ***, port e1a.net.ifgrp.lacp.link.inactive: ifgrp a0b, port e1a has transitioned to an inactive state. The interface group is in a degraded state.netif.linkDown: Ethernet e1a: Link down, check cable.
~
netif.linkUp: Ethernet e1b: Link up.
netif.linkUp: Ethernet e1a: Link up.
- 在确认布线与该端口连接良好后,问题仍然存在。
- 将端口连接到其他已知正常工作的交换机端口后,问题仍然存在。
- 重新插拔卡后,问题仍然存在。