跳转到主内容

A400 HA互连端口已关闭

Views:
8
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

  • AFF A400
  • HA互连连接、用于连接e0a和e0b端口。

问题描述

  • 两个节点中的HA互连端口均脱机。示例: 
节点A
[NODE-A: kernel: netif.linkDown:info]: Ethernet e0a: Link down, check cable.
[NODE-A: kernel: netif.linkDown:info]: Ethernet e0b: Link down, check cable.
[NODE-A: cf_main: cf.fsm.takeoverByPartnerDisabled:error]: Failover monitor: takeover of NODE-A by NODE-B disabled (HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support).
[NODE-A: cf_main: cf.fsm.takeoverOfPartnerDisabled:error]: Failover monitor: takeover of NODE-B disabled (HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support).
[NODE-A: monitor: monitor.globalStatus.critical:EMERGENCY]: Controller failover of NODE-B is not possible: HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support. There are not enough spare disks.
[NODE-A: statd: cf.takeover.disabled:alert]: HA mode, but takeover of partner is disabled due to reason : HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support.
[NODE-A: statd: ic.HAInterconnectDown:error]: HA interconnect: Interconnect down for 15 minutes: all links are down
[NODE-A: statd: callhome.hainterconnect.down:alert]: Call home for HA INTERCONNECT DOWN due to all links are down.
 
节点B
[NODE-B: kernel: netif.linkDown:info]: Ethernet e0a: Link down, check cable.
[NODE-B: kernel: netif.linkDown:info]: Ethernet e0b: Link down, check cable.
[NODE-B: cf_main: cf.fsm.takeoverByPartnerDisabled:error]: Failover monitor: takeover of NODE-B by NODE-A disabled (HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support).
[NODE-B: cf_main: cf.fsm.takeoverOfPartnerDisabled:error]: Failover monitor: takeover of NODE-A disabled (HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support).
[NODE-B: monitor: monitor.globalStatus.critical:EMERGENCY]: Controller failover of NODE-A is not possible: HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support. There are not enough spare disks.
[NODE-B: statd: cf.takeover.disabled:alert]: HA mode, but takeover of partner is disabled due to reason : HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support.
[NODE-B: statd: ic.HAInterconnectDown:error]: HA interconnect: Interconnect down for 15 minutes: all links are down
[NODE-B: statd: callhome.hainterconnect.down:alert]: Call home for HA INTERCONNECT DOWN due to all links are down.
  • 两个节点的SFP信息均显示在 ::> system node run -node * -command sysconfig -a 输出中、但端口已关闭:

节点A

   slot 0: Dual 10G/25G Ethernet Controller CX5
      e0a MAC Address:   d0:39:ea:2b:c3:31 (auto-unknown-fd-down)
        SFP Vendor:      Molex
        SFP Part Number:   1111455002
        SFP Serial Number:  93A2023020111
      e0b MAC Address:   d0:39:ea:2b:c3:32 (auto-unknown-fd-down)
        SFP Vendor:      Molex
        SFP Part Number:   1111455002
        SFP Serial Number:  93A2012020222
      Device Type:     CX5 PSID(NAP0000000006)
      Firmware Version:   16.26.4012

节点B

   slot 0: Dual 10G/25G Ethernet Controller CX5
      e0a MAC Address:   d0:39:ea:2b:c2:c1 (auto-unknown-fd-down)
        SFP Vendor:      Molex
        SFP Part Number:   1111455002
        SFP Serial Number:  93A2023020111
      e0b MAC Address:   d0:39:ea:2b:c2:c2 (auto-unknown-fd-down)
        SFP Vendor:      Molex
        SFP Part Number:   1111455002
        SFP Serial Number:  93A2012020222
      Device Type:     CX5 PSID(NAP0000000006)
      Firmware Version:   16.26.4012

  • ::*> system ha interconnect status show将显示"" link 0 、并且 link 1 处于关闭状态。示例

::> set advanced

::*> system ha interconnect status show
                     Node:node-1
            Link 0 Status: down
            Link 1 Status: down
         Is Link 0 Active: false
         Is Link 1 Active: false
    IC RDMA Connection: up
                     Node:node-2
            Link 0 Status: down
            Link 1 Status: down
         Is Link 0 Active: false
         Is Link 1 Active: false
       IC RDMA Connection: up
2 entries were
displayed.

  • 重新固定每个HA互连SFP和缆线连接后、问题描述仍会保留。
  • 对 同一节点中的HA互连端口执行环回测试会使这两个端口恢复联机。
  • 两个节点均保持联机、但不会接管:

::*> storage failover show -node *
                Takeover      
Node       Partner     Possible State Description  
-------------- -------------- -------- -------------------------------------
node-1     node-2     false   Waiting for node-2, Takeover is
                    not possible: Storage failover
                    interconnect error, NVRAM log not
                    synchronized
node-2     node-1     false   Waiting for node-1, Takeover is
                    not possible: Storage failover
                    interconnect error, NVRAM log not
                    synchronized
2 entries were displayed.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.