vserver fcp topology show 命令输出未完成
适用场景
- ONTAP 9
- FCP
问题描述
""vserver fcp topology show
命令输出不完整,并且不包含所有逻辑接口
::> net int show -vserver vserver_1
(network interface show)
Logical Status Network Current Current Is
Vserver Interface Admin/Oper Address/Mask Node Port Home
----------- ---------- ---------- ------------------ ------------- ------- ----
vserver_1
node_1_fc_lif_1 up/up 20:00:00:a0:xx:xx:xx:xx node_1 0e true
node_1_fc_lif_2 up/up 20:01:00:a0:xx:xx:xx:xx node_1 0f true
node_2_fc_lif_1 up/up 20:02:00:a0:xx:xx:xx:xx node_2 0e true
node_2_fc_lif_2 up/up 20:03:00:a0:xx:xx:xx:xx node_2 0f true
在以下示例中,仅显示 3 个条目,而不是 4 个条目(对于每个 LIF ):
:*> vserver fcp topology show
Domain Logical Port
Vserver LIF Name Id Name WWN Count
------- -------------- ------ ------------------- ----------------------- -----
vserver_1
node_1_fc_lif_1 1 switch1 10:00:c4:f5:7c:xx:xx:xx 24
node_1_fc_lif_2 1 switch2 10:00:c4:f5:7c:xx:xx:xx 24
node_2_fc_lif_1 1 switch1 10:00:c4:f5:7c:xx:xx:xx 24
3 entries were displayed.