COOTP-48吧:对于12或24以外的任何数量的驱动器、系统级诊断失败
问题描述
运行系统级诊断时、如果
AFF A250和AFF C250、FAS500f系统包含任意数量的内部驱动器、而不是12或24个、则NVMe驱动器的System Scan
将失败。
诊断控制台输出示例如下:
1) Scan System
2) Test System (must scan system, first)
3) Test Memory (must scan system, first)
4) Stress-Test System (must scan system, first)
5) Show VPD Information
6) Show FW Revision
7) Show MAC Address
8) Show Logs
9) Reboot (BMC Power Cycle) Controller to LOADER
Warning: Persistent logging to boot media is not available.
Terminal session logging is recommended.
Select a number 1-9 to execute the respective command: 1
System Scan Start: 2022-10-06 18:15:37
NVMe Drive: FAILED
Expect:24 Present:18 <<<<<< This system has 18 internal drives installedSlot PN SN
NVMeSlot0 X4011S17333T8NTE S60NNA0Rxxxxxx
...