问题描述

  • 频繁的心跳未命中,这可能导致接管一个节点。
  • 在心跳未命中之前,正在进行接管的节点将无响应,在此期间没有节点日志。
  • 发生接管的无响应节点不会在问题发生时报告任何硬件错误。
  • 接管的合作伙伴节点通常会记录 SCSI IO 传输错误、NVMM 镜像同步失败、QP 错误、HA 错误等。
  • 合作伙伴节点日志示例: 

Jan 01 01:01:01 [node_name: DR_heartbeat_thread: cf.ic.xferTimedOut:error]: HA interconnect: MCC_DRSOM transfer timed out.
Jan 01 01:01:01 [node_name: DR_heartbeat_thread: rdma.rlib.event.error:debug]: QP drsom_hb event error: client disconnect.
Jan 01 01:01:01 [node_name: iw_cxgbe: nvmm.mirror.aborting:debug]: mirror of sysid 1, partner_type HA Partner and mirror state NVMM_MIRROR_ONLINE is aborted because of reason NVMM_ERR_MIRROR_COMPLETION.
Jan 01 01:01:01 [node_name: rastrace_dump: rastrace.dump.saved:debug]: A RAS trace dump for module IC instance 0 was stored in /etc/log/rastrace/IC_0_20250101_01:01:01:123456.dmp.
Jan 01 01:01:01 [node_name: cf_firmware: cf.ic.xferTimedOut:error]: HA interconnect: OFW transfer timed out.
Jan 01 01:01:03 [node_name: cf_main: cf.fsm.takeoverByPartnerDisabled:error]: Failover monitor: takeover of node_name-01 by node_name-02 disabled (HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support).
Jan 01 01:01:04 [node_name: cf_main: cf.fsm.partnerNotResponding:notice]: Failover monitor: partner not responding
Jan 01 01:02:01 [node_name: cf_main: cf.fsm.takeoverCountdown:info]: Failover monitor: takeover scheduled in 10 seconds
Jan 01 01:02:10 [node_name: cf_main: cf.fsm.takeover.noHeartbeat:alert]: Failover monitor: Takeover initiated after no heartbeat was detected from the partner node.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.