ONTP-320179:磁盘类型X357_SLBPE3T8ATE固件NA51出现高故障率
问题描述
- 磁盘驱动器断开连接
pmcsas_admin_0: sas.adapter.debug:info]: params: {'adapterName': '0a', 'debug_string': 'BAD destination on OPEN (0x14) -- delaying: dev 0b.00.22, cdb 0x28:d98cc920:0008 (0/90181), NDU 0x0'}
- 系统尝试恢复驱动器
scsi_cmdblk_strthr_admin: disk.timeout.flush.start:debug]: Aggressive timeout flush started on disk 0a.00.22.
- 磁盘驱动器最终丢失
svc_queue_thread: cf.disk.inventory.mismatch:error]: Status of the disk ?.? (6000C500:EC999027:500A0981:00000001:00000000:00000000:00000000:00000000:00000000:00000000) has recently changed or the node (node-01) is missing the disk.