COTP-248951:ONTAP升级后、集群交换机报告SwitchUnachable_Alert (IP地址不可访问)
问题描述
- 升级ONTAP后、一个或多个节点报告无法访问这些集群交换机:
ClusterA::*> system switch ethernet showSwitch Type Address Model--------------------------- ------------------ ---------------- ---------------Switch-A1 cluster-network 1.2.3.4 OTHERSerial Number: UnknownIs Monitored: falseReason: IP address not reachableSoftware Version: Cumulus Linux version 5.4.0 running on MellanoxTechnologies Ltd. MSN2010Version Source: LLDPSwitch-A2 cluster-network 1.2.3.5 MSN2100-CB2FCSerial Number: UnknownIs Monitored: falseReason: IP address not reachableSoftware Version: Cumulus Linux version 5.4.0 running on MellanoxTechnologies Ltd. MSN2010Version Source: LLDP- 系统运行状况警报show输出中也会显示一条警报:
Node: ClusterA-01Alert ID: SwitchUnreachable_AlertResource: Switch-A1Severity: MajorIndication Time: Fri May 03 09:39:17 2024Suppress: falseAcknowledge: falseProbable Cause: The ethernet switch's IP address is not reachable from the local node.Possible Effect: Monitoring of the switch and log collection will not function.Corrective Actions: Ensure that the IP address is reachable or specify the correct reachable IP address.Node: ClusterA-01Alert ID: SwitchUnreachable_AlertResource: Switch-A2Severity: MajorIndication Time: Fri May 03 09:39:18 2024Suppress: falseAcknowledge: falseProbable Cause: The ethernet switch's IP address is not reachable from the local node.Possible Effect: Monitoring of the switch and log collection will not function.Corrective Actions: Ensure that the IP address is reachable or specify the correct reachable IP address.