跳转到主内容

CONTP-207251:如果集群交换机名称与CDP/LDP不同、则错误地触发ClusterSwitchConnectivity _Alert

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

问题描述

  • 误报ClusterSwitchConnectivity、"system Health alAlert show"输出中报告了"ClusterSwitchConnectivity、Alert"。
  • 集群网络布线正确且运行状况良好
  • 交换机名称与CDP/LDP不同

Node: Node-01
Alert ID: ClusterSwitchConnectivity_Alert
Resource: Node-01
Severity: Major
Indication Time: Sun Mar 10 13:38:22 2024
Suppress: false
Acknowledge: false
Probable Cause: The ethernet switch, with the name "Switch-01(FOCXXXXXXXXX)", is not connected to all of the nodes in the cluster.
Possible Effect: If one cluster switch fails, "Node-01" might lose access to the cluster.
Corrective Actions: Verify that the switch "Switch-01(FOCXXXXXXXXX)" is connected to the node "Node-01" and that the switch's name has not been modified due to a change in the switch's link discovery protocol used for advertisements.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.