跳转到主内容

CHS-778:NVDIMMBadithAlert原因:在配备NVDIMM的系统上出现固件错误

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

问题描述

AFF A800、AFF A320、AFF A400、FAS8300或FAS8700存储系统
EMS:Sun Jun 06 17:17:15 -0700 [NetApp1: nphmd: hm.alert.raised:alert]: Alert Id = NVDIMMBadHealthAlert , Alerting Resource = /dev/nvdimm0:NetApp1 raised by monitor controller
 
部分: NVDIMM状态
Total NVDIMM on this platform is 2
--------------------------------------------------
DIMM(/dev/nvdimm0) Page:0
DIMM(/dev/nvdimm0):
--------------------------------------------------
Controller Ready: Yes
Controller Busy: No
Energy Policy managed by: HOST
Save_N Low During CSAVE: Yes
Save_N Enabled(ARMED): Yes
Data on the Flash: NotValidModule is Health: No
Module Status(0x0040): NVDIMM FIRMWARE error
Flash Lifetime: 94%
Flash Lifetime Status: Normal

 
示例运行状况警报:::
> system Health alAlert
show
Node: node02
Alert ID: NVDIMMBadHealthAlert
Resource: /dev/nvdimm0
Severity: Major
Indication Time: Tue Dec 03 02:15:51 2024
Suppress: false
Acknowledge: false
Probable Cause: NVDIMM "NVDIMM-N 0 (DIMM-11)" on node "node02" is indicating a degraded status.
Reason: NVDIMM FIRMWARE error.
Possible Effect: Potential data loss as the NVDIMM becomes degraded.
Corrective Actions: Contact technical support for assistance with NVDIMM module replacement.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.