跳转到主内容

CHW-778:NVDIMMBadHealthAlert 原因:FIRMWARE 错误,在配备 NVDIMM 的系统上

Views:
29
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
HW
Last Updated:

问题描述


 
EMS
[hm.alert.raised:alert]: Alert Id = NVDIMMBadHealthAlert , Alerting Resource = /dev/nvdimm0:NetApp1 raised by monitor controller
环境状态命令显示 [NVDIMM0 Health BAD]
::> system node run -node local environment status
Sensor Name        State      Current   Critical    Warning    Warning   Critical
                     Reading     Low      Low      High     High
-------------------------------------------------------------------------------------------------
NVDIMM0 Firmware ERROR
NVDIMM0 Health                BAD
PVCCIN CPU0        normal      1773 mV     9 mV     19 mV    2459 mV    2469 mV   


AutoSupport 部分: NVDIMM-STATUS
Total NVDIMM on this platform is 2
--------------------------------------------------
DIMM(/dev/nvdimm0) Page:0
DIMM(/dev/nvdimm0):
--------------------------------------------------
Controller Ready: Yes
Controller Busy: No
Energy Policy managed by: HOST
Save_N Low During CSAVE: Yes
Save_N Enabled(ARMED): Yes
Data on the Flash: NotValidModule is Health: No
Module Status(0x0040): NVDIMM FIRMWARE error
Flash Lifetime: 94%
Flash Lifetime Status: Normal

 
健康警报示例:
::> system health alert show
Node: node02
Alert ID: NVDIMMBadHealthAlert
Resource: /dev/nvdimm0
Severity: Major
Indication Time:
Suppress: false
Acknowledge: false
Probable Cause: NVDIMM "NVDIMM-N 0 (DIMM-11)" on node "node02" is indicating a degraded status.
Reason: NVDIMM FIRMWARE error.
Possible Effect: Potential data loss as the NVDIMM becomes degraded.
Corrective Actions: Contact technical support for assistance with NVDIMM module replacement.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.