问题描述

  • EMS 在 FAS8300、FAS8700、AFF A400、AFF A250 和 FAS500f 平台中报告 BootmediaWarnAlert。
    [Node A: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nphm: BootmediaWarnAlert[mSATA (XXXXXXX)].
  • system health alert show命令产生以下内容:
    Node cluster1-01
    Monitor controller
    Alert ID BootmediaWarnAlert
    Alerting Resource mSATA (xxxx)
    Subsystem Motherboard
    Indication Time Thu Nov 18 06:05:26 2021
    Perceived Severity Major
    Probable Cause hardware_degrading
    Description Boot device is wearing out due to write operations in the form of regular updates.
    Corrective Actions 1. Contact technical support to obtain a new boot device.
    2. If possible, perform a takeover of this node and bring the node down for maintenance.
    3. Refer to the "Boot media replacement guide for your given hardware platform" to replace the boot device.
    4. Update the boot device with the appropriate Data ONTAP version.
    5. Bring the storage system online.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.