CFSHELF-2190:在具有内部 NVMe 驱动器的系统上间歇性地看到 ses.status.electronicsWarn 和 ses.status.ModuleError
问题描述
- 在具有内部 NVMe 驱动器的系统上,ONTAP 可能会间歇性地报告与用于内部盘架管理的存储盘柜服务(SES)的通信错误
- 此情况会在几分钟到一个小时后清除
- 以下是在此情况下记录的示例事件:
20:18:13 +0000 [node1: dsa_worker2: ses.status.electronicsWarn:error]: FS4483PSM3E (S/N SHFNC23200XXXXX) shelf 0 on channel 0s environmental monitoring warning for SES electronics 1: communication error. ; enclosure services hardware failed This element is on the rear of the shelf at the top, on shelf module (A).
20:18:13 +0000 [node1: dsa_worker2: ses.status.ModuleError:alert]: FS4483PSM3E (S/N SHFNC23200XXXXX) shelf 0 on channel 0s PCI switch error for PCI Switch 1: status not available; status not available. This element is on the rear of the shelf at the top, on shelf module (A).
22:18:49 +0000 [node1: dsa_worker2: ses.status.electronicsInfo:info]: FS4483PSM3E (S/N SHFNC23200XXXXX) shelf 0 on channel 0s environmental monitoring information for SES electronics 1: normal status.
22:18:49 +0000 [node1: dsa_worker2: ses.status.ModuleInfo:info]: FS4483PSM3E (S/N SHFNC23200XXXXX) shelf 0 on channel 0s PCI switch information for PCI Switch 1: normal status.