问题描述

  • 在BMC升级期间会显示以下系统运行状况警报:

::> system health alert show
        Node: Node-01
      Alert ID: SPAutoUpgradeFailedMajorAlert
      Resource: SP Upgrade
      Severity: Major
   Indication Time: Mon Dec 09 20:24:36 2024
      Suppress: false
     Acknowledge: false
   Probable Cause: A Service Processor automatic firmware update failure
           was detected, which can result in Service Processor
           not being updated to the latest available compatible
           firmware package.
   Possible Effect: Suboptimal system behavior can result from Service
           Processor not being updated to the latest available
           compatible firmware package.
Corrective Actions:  1. Use the "system service-processor image show" command to display the firmware version that SP is currently booted from.
           2. Manually upgrade Service Processor by using the "system service-processor image update" command.
           3. Allow sufficient time for the system to update Service Processor firmware to the specified SP firmware package.
           4. Contact the technical support if the alert persists.
 
  • 事件日志中会报告以下警报、但BMC稍后会更新为捆绑版本:

[Node-01: servprocd: sp.servprocd.upd.evts:debug]: params: \{'reason': 'PostUpdate Check : SP firmware post-update check has FAILED'}
[Node-01: nphmd: hm.alert.raised:alert]: Alert Id = SPAutoUpgradeFailedMajorAlert , Alerting Resource = SP Upgrade raised by monitor controller
[Node-01: servprocd: sp.servprocd.upd.evts:debug]: params: \{'reason': 'SP Firmware network update has been successfully scheduled from  10.9 to 10.9P2'
[Node-01: servprocd: sp.servprocd.upd.evts:debug]: params: \{'reason': 'SP Firmware network update from 10.9 to 10.9P2 has been triggered.'
[Node-01: nphmd: hm.alert.cleared:notice]: Alert Id = SPAutoUpgradeFailedMajorAlert , Alerting Resource = SP Upgrade cleared by monitor controller

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.