CFBMC-1667:存储系统过早报告币形电池LNC和LCR阈值错误
问题描述
- 事件
monitor.rtcHighPower
和monitor.rtcNormal
会在EMS日志中进行报告[NODE-02: env_mgr: monitor.rtcHighPower:error]: Real-time clock battery voltage is above normal (P3.3V Batt is warning high (3307 mV).).
[NODE-02: env_mgr: monitor.rtcNormal:notice]: Real-time clock battery voltage is normal P3V3_BATT: Voltage Sensor 26 UNC
如所示system controller service-event show
::*> system controller service-event show
Node ID Event Location Event Description
---------------- --- ---------------------------------- ----------------------
NODE-02 1 Controller B on Chassis 1 P3V3_BATT: Voltage Sensor 26 UNCP3V3_BATT
状态显示nc
inbmc status -d
ipmi_sensors
============
Sensor Name | Current | Unit | Status | LCR | LNC | UNC | UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
P3V3_BATT | 3.308 | Volts | nc | 2.538 | 2.695 | 3.308 | 3.448